Thursday, October 18, 2007

SketchUp + HVAC-CALC, part 2

You've read it here first. Now someone closer to the subject area implemented it: Energy Analysis Tool for SketchUp.

Told you.

Random Notes: Timing and Blueprints

Random note #1: One thing I have not regretted, in a hindsight, that I've started the wiring project right now - in local mid-season. When the insulation is disturbed, it doesn't function properly anymore, and had this happened in the middle of the summer (or in the middle of the winter for those farther North), it would've been bad.

Random note #2: SketchUp is the best thing since sliced bread for DIY projects. More and more professionals are starting to realize the importance of it (see the article on timber framing, for example). It works for project at almost any scale - the house model I've built, for example, has everything from the yard on the top of the scale to individual screws in places where I've laid conduit, on the bottom of it. Start with 3d Warehouse (Thai House Blueprints is a beautiful example), don't forget the SketchUp Blog.

Tuesday, October 16, 2007

The Great Wiring Project, part 4

The Great Wiring Project, part 1
The Great Wiring Project, part 2
The Great Wiring Project, part 3



This one is going to be really short: I thought I'd be able to get away without a patch panel. No such luck. Off looking for one. Suggestions welcome.

(to be continued)

Monday, October 15, 2007

The Great Wiring Project, part 3

The Great Wiring Project, part 1
The Great Wiring Project, part 2



There is this usual dilemma - whether to run just the wires, or run the conduit. Given the fact that a) the opportunity presented itself and b) I know I would be able to utilize all the paths the conduit offers and not simply show it off to my friends, the decision was made to run the conduit.

Oh boy.

Remember, at the very beginning I said forget elegant? My particular problem (which is the more likely to happen to you the more owners it had) was caused by the fact the house's been remodeled. As a result, observations on one part of the structure were absolutely not applicable to another. To add insult to injury, the addition was partly a hack job (imagine my surprise when I uncovered a 4x4 beam in the middle of a wall... On top on two 2x4s... Turned out, there was a door before...)

There was a phrase in a book on wiring I read, "Be prepared to drill a few exploratory holes". Actually, that was a euphemism. They probably meant "Be prepared to tear the walls down".

Would the process be easier if I decided to run wires? Not really. It would only be easier if I was familiar with the building blueprints and was doing work on the same floor plan for the umpteenth time. For a case of a single DIY work, no, it wouldn't have been.

One reason why it wouldn't have been possible to even piggyback and/or replace existing wiring while running wires (as opposed to conduit) is that existing wiring is stapled down to studs very tightly and it either doesn't move at all, or any part that is thicker than the actual cable you're trying to piggyback will invariably get stuck at the first staple you meet.

Another one is that insulation offers a formidable obstacle. It is not really possible to guess where the fish tape is going (and those words about "non-curling" fish tape are a joke, too).

A word about fish tapes and cables - give it a LOT of padding. A run from the left side of a 14 ft wide room to the right side, up and over the ceiling, took whopping 35 feet of conduit - so had I bought a 25ft fish tape, I'd be kicking myself in the butt right now. Fortunately, I've bought a 50ft one - but now I'm not even sure *that* would be sufficient (the project is far from over). Crossing my fingers for now.

Back to conduits...

Rigid plastic conduit is a joy to work with (I've used 1/2" for single cable runs, 3/4" for double cable runs and 1" for the trunk). Flexible plastic conduit (there are several color coded varieties, out of which I've seen high voltage blue and low voltage orange) is surprisingly rigid at times - and don't let it spring in your hands and knock you on the forehead (ask me how I know). Did I mention wear goggles at all times?

Snap-on connectors for the flexible plastic conduit are, in fact, one-time use - it's a pain to disconnect one once you snapped it on. I've used threaded ones to connect conduit to the boxes, just to save myself some aggravation in case if I ever have to disconnect one.

Boxes. There's not much difference between cutting a smaller hole and using an existing work box, or cutting a bigger hole and using a new work box. If you want to route the conduit to existing wall plate, second option is unavoidable - unless the box can be taken out. I decided to use new work boxes everywhere (except one really simple run) - there's lots of holes to patch already anyway, a few extra doesn't make much difference, but makes the general quality of installation much more enjoyable.

The Great Wiring Project, part 1
The Great Wiring Project, part 2
(to be continued)

Sunday, October 14, 2007

The Great Wiring Project, part 2

The Great Wiring Project, part 1
The Great Wiring Project, part 3



I just realized that this story becomes chaotic pretty fast. Hmm... Let it be - and when it's all said and done, I'll reorganize it so it makes chronological sense for those planning, and find it a permanent place at DZ site.

So...

If you think you have all the tools, think again. The only tool I had to buy was a high torque drill - your usual 1/3 HP kind gets stuck when equipped with bits starting about 7/8", and, in general, more powerful tools mean less kickback and more precision.

Drill bits differ - spades are cheaper but very rough, splinter wood badly on exit, but sometimes may be the only option. Forstner bits are much more expensive, but produce an exact opening - and unlike spades which go astray under slightest provocation, they are self-guiding and it is possible to use one to enlarge a preexisting hole. Remember that Forstner bits are usually pretty short - and the lengths you will have to drill through may exceed 8" (visualize door header left in the wall when someone decided they no longer wanted a door there).

Instead of buying a long bit, buy a short one and an extender - otherwise you might end up a short bit *and* a long bit, which is not that cost effective keeping in mind that one extender will work with many bits.

I will try to avoid using center bits for a while - the Ridgid one I bought broke on the first try - the center piece disengaged from the rest of the bit and got stuck in the wood. Took me lengthy and painful efforts to get it out of there - it happened in quite an inaccessible place.

Absolute must for this project (in my book) is a jigsaw - though you may get away with a drywall knife. It'll just take longer. Decent fish tape won't hurt, either.

A really bad surprise was the amount of dust drywall generates. The cleanest solution is to have a helper with a shopvac standing next to you - worked pretty well for me. Nevertheless, invest in a decent respirator (expensive) and goggles (cheapest and biggest work just fine). Cover all things with vents on the upside with a dust-opaque cloth (plastic is not a good idea because it will not let the air from those vents up - you're risking to kill your equipment).

Don't forget to replace the HVAC filters when you're done.

Be prepared that you will damage or destroy insulation behind the walls you're opening, so plan on either taking extreme measures not to contaminate it with drywall dust (I don't think it's possible), or live with it, or reinforce or replace the insulation altogether (may or may not be possible, depending on the location and size of the opening). Also remember that fiberglass does get under your skin - you may not notice it within first five minutes, but you will for sure notice it within first five days.