Sunday, July 27, 2008

Extra Insulation For The Poor

Extreme circumstances call for extreme measures.

If you are not happy with your single pane windows, but don't have enough money to replace them with something better, and willing to live with the ugliness of a temporary solution (in these times of failing employment and skyrocketing prices of everything this may be quite acceptable), here's a way to deal with it:

Install a sheet of expanded polystyrene into the window.

They come in different sizes, the most convenient would be 2'x4' (or 4'x8' if you have a truck).

4x8 2" thick costs (at the moment of writing at my location) about $23. 2x4 costs less than $6.

2" thick sheet is R-7.8 (for comparison, a single pane window is R-1, triple pane window is R-3).

Thinner sheets cost less, but have significantly lower R value, so you be the judge of what you need.

These sheets are not completely opaque - they let just about the same amount of light as a heavy curtain, with the added benefit of preserving the spectrum (with a slight blue hue because of blue lettering on them).

A nice tool to cut these sheets with, should that be necessary, is a Japanese (pull style) double blade saw such as Vaughan Bear - it's a complete topic in itself, you'll love using this tool, much more exact and rewarding than a comparable size push saw.

Installing these makes a hell of a difference.

Thursday, July 10, 2008

The other side of the coin: mini-splits

Just returned from a trip to Eastern Europe.

Just as forced air HVAC systems are the king in the US, mini-splits and multi-splits rule over there. Of course, it is dictated by the environment - they are mostly being slapped on the walls of existing high rise buildings, where the choices are extremely limited - either mini-splits, or window shakers which are noisy and obstruct sunlight, or indoor portable units, which occupy a lot of already limited space.

I watched one of those being installed. Well, guess what, it is just as bad as it is here - the condenser turned out to be installed noticeably askew when we momentarily lost our vigilance, installers were visibly taken back by questions about how exactly they were charging the unit and eventually cut us off with "It's already been charged by the manufacturer", unfazed by questions about the relations between tubing length and operating pressures... Oh well, let's just hope that the HVAC manufacturer did their best and came up with some incredibly smart way to take that into account.

On the down side: God! They are sure an eyesore. Condenser is more or less OK since it is outside, but the air handler is HUGE.

On the up side: they seem to be orders of magnitude more efficient than big iron HVACs of US are. And, they're virtually silent, especially the condenser (it must be said, though, that I was witnessing the high end inverter system, cheaper models may not be as quiet).

Bottomline: if one of my HVACs decides to go south, I'll be replacing it with several mini-splits or multi-splits.

Even though they are said to be expensive, I'm sure that with my overinflated demand for quality I'll get just about the same price as I would get for a single forced air HVAC of similar capacity, plus advanced ability to place the unit where I want, not where the ducts go, plus advanced scheduling and shutoff capabilities, plus zoning out of the box, plus truckload of free space in the walls where the ducts used to be.

/me off investigating...

Sunday, December 23, 2007

Tuesday, December 18, 2007

One Size Fits All, or Reflections on EPA guidelines

So here cometh a fresh pair of thermostats (Honeywell RTH7500 and RiteTemp GPMG8085C), both equipped with default schedules taken from EnergyStar ® Program Requirements for Programmable Thermostats: Partner Commitments (look for Table 2: Acceptable Setpoint Times and Temperature Settings). It was summer, and the default settings were too cold for us, so we changed them.

But the defaults for the heating season were left in place.

Now that the heating season is here, and it is eventually getting quite cold outside, several interesting things are popping up.

First of all, let's take a look at default EPA compliant settings.

Wake: 6AM, 70°F.
Day: 8AM, 62°F.
Evening: 6PM, 70°F.
Sleep: 10PM, 62°F.

Then, let's go back and read the long rant about whether you should shut off your A/C or leave it running.

Then, let's take a look at the temperature spread for the schedule above. 8°F.

That's quite a lot.

The very reason I've started thinking about writing this article is that one of my units (Lennox split), being perfectly capable in cooling mode, seems to either hit the balance point, or otherwise severely degrade its performance, when the ambient temperature drops lower than about 45°F - and, as a result, it is unable to bring the zone it serves from 62°F to 70°F in two hours.

Even worse the temperature actually drops to about 65°F by 6AM, and it barely makes it to 68°F by 8AM - forget 62 to 70.

While this is definitely quite uncool, it also points out another fact that is not on the surface: the unit works at the top of its efficiency curve. It doesn't cycle, it spends initial 10-20 minutes approaching the design efficiency and stays there.

That was the positive, now, another negative - since it serves two rooms, one of which is about five times size the other - guess what, by the end of the two hour run the smaller room is HOT. Balancing the dampers manually will not help since it'll shoot the balance for other conditions - like, the evening, when the ambient temperature is significantly higher and the runtime of the unit is very short in comparison.

So, what's the point?

  • One should carefully examine defaults;
  • You can't get away without actually zoning the house - unless you want to shuffle everything all the day or suffer;
  • It would *really* pay back to come up with an idea to figure out to anticipate the *actual* performance of the unit for varying circumstances and make the system issue recommendations to you about what you should do in any particular case;
  • Which would imply the knowledge base and rule engines to analyze input and figure out dependencies (homework: see Google's statements how having access to massive amounts of data helps to figure out the trends and make correct decisions);
  • It would help to share data between installations (see how Valve managed to make Half Life 2 the most playable game for the same hardware utilizing statistics) and applying some brains;
Damn! DZ is going enterprise.

Hmm... Turned out not quite the way I started it - but oh well, I'll just leave it at that.

Saturday, December 8, 2007

Green Dryer

Looking outside of my window and seeing a giant plume of steam coming out of my dryer's exhaust.

Immediately thinking that next time I'll be doing remodeling around the laundry room, or building my own house, I'll definitely install an ERV capturing all that heat that is being wasted by the dryer in the heating season, and a bypass allowing it to escape in the cooling season.

Also thinking that it would be a dumbest idea possible to direct the dryer exhaust into the house because of associated humidity and smell.