Q: Default thermostat settings cause too much of a temperature swing, how do I make my thermostat more sensitive?
A: You increase the value of P for the PID controller associated with this thermostat. Default value of P (1.0) corresponds to a deadband from 1°C below the setpoint to 1°C above. Increasing P to 2 will cause that to change to a range from 0.5°C below the setpoint to 0.5°C above.
Likewise, if you want to dumb down your thermostat because the HVAC switches on and off too often, you need to decrease the value of P. However, be careful, for short cycling (the HVAC term for this phenomenon) may have different causes - but you'll be able to easily see the cause for them on charts DZ generates.
Q: Will there be a UI control for that?
A: Yes.
Thursday, December 3, 2009
FAQ: Thermostat Sensitivity
Posted by
vt
at
12/03/2009 10:13:00 AM
0
comments
Labels: deadband, FAQ, hysteresis, PID Controller, sensitivity, short cycling, thermostat
Friday, July 20, 2007
Short Take: Hysteresis in RTH7500
Frequently asked question with a very vague answer - what is the hysteresis (a.k.a. dead band) of my thermostat?
For Honeywell RTH7500, the measured (therefore not exact) typical value is about 1°C (about 1.8°F) - for the sensor located in the room behind the wall where the thermostat is.
Worst observed value is 2.5°C (about 6.3°F) - for the sensor located on the first floor (the thermostat is at the second) - this is not actually a property of the thermostat, but rather an indication of how badly the airflow was designed.
Another question - can hysteresis be controlled in RTH7500? The answer is: probably not.
If it can, there's no way to do it that is described in the documentation that is sold with the thermostat (yes, I found the manual, feel free to ask me what those numbers mean).